What is Service Factor?
Reply
Service Factor(SF) is a multiplier that when multiplied by the horsepower of the motor indicates the total permissible horsepower loading that may be carried when the motor is operating at rated voltage and frequency. The most important thing to remember when replacing a motor is that the replacement motor's horsepower times its service factor must be equal to or greater than the original motor's horsepower times its service factor. The Service Factor rating can be found on the motor label. See Step 4 of our How to Read a Pool Motor Label guide.
Reply
Am needing to replace electric motor for Power-Flo Matrix Pump by Hayward. Reading instructions for seal replacement seems to lead to motor removal. Once motor removed from pump housing, how do I remove the collar and impeller? Will it be obvious once I see it? Or will other tools or work be required to swap that to new motor? Thanks
Reply
Hi Gary, We have a How to Guide on How To Replace a Hayward Power Flo Shaft Seal which should answer all of your questions. We also have a Video on How To Replace a Pool Pump Motor which should be helpful as well.
Reply
IS THIS THE SAME MOTOR AS MINE WITH # SPX1510Z1XE-01, WHICH IS A FEW YEARS OLD? PLEASE GET BACK TO ME ASAP, AS MY MOTOR IS CRACKED & WATER IS LEAKING OUT OF MY POOL!
Reply
Hi Gayle, Yes this would be the same motor as your SPX1510Z1XE-01 motor.
Reply
IS THIS MOTOR THE SAME AS MY SEVERAL YEAR OLD HAYWARD MOTOR WITH THESE ID#'S SP1510Z1XEHC &/OR 196035-01. I HAVE A CRACK IN MY MOTOR AND I REALLY NEED YOUR HELP ASAP SO I CAN ORDER THE CORRECT MOTOR. THANKS!
Reply
The SPX1510Z1XE part number 5111-86 would be the correct replacement motor for you powerflow matrix 1hp pump. I would also recommend you replace you shaft seal when replacing the motor which is part number SP1500KA.
Reply
The pump/strainer is leaking between the motor and strainer. There's play between the motor and the strainer. Is there a possible quick fix? Is this a common breakdown. Seems the cause would have been from the struggle to open the strainer lid. HELP!
Reply
Typically this type of leaking is caused by a bad shaft seal. If you do have a Hayward Power Flo then I would suggest a Hayward Power-Flo Tune Up Kit which includes the shaft seal and all of the orings for the pump.