$4,699.00

Qty:

By Hayward Pool Products


Details

Top

Model # W3HP31005T

Warranty 1-Year Parts-Only Warranty

Dimensions 31.5 x 40.2

Alternate Part #'s W3HP21104T, HPPW3HP31005T

Product Description

For the after-market and new construction, the HeatPro is the only round, a compact designed heat pump that combines excellent energy efficiency, industry leading quiet operation, easy installation, and for superior value, performance, and reliability, a standard ultra gold fin evaporator coil for superior coastal corrosion resistance.

 

  • Titanium Heat Exchanger - Excellent salt water and chemical corrosion resistance
  • Exclusive 'Ultra Gold' Evaporator Coil corrosion resistant especially in coastal areas
  • Quiet Operation - quiet backyard environment
  • AHRI Certified Performance - Independent lab certified performance ensures the value of the purchase
  • Round Design - Easily fits through gates and takes up less space on the equipment pad
  • 2in x 2 1/2in CPVC Union Plumbing Connections - Common union for installation or service, adapts to larger plumbing recommended for greater efficiencies
  • Lighter Weight - Less than 250 lbs.
  • HEAT/COOL
  • Low Ambient
  • COP 6.4

Product Specifications

BTU:
100,000 BTU
Special Feature:
Heat/Cool
Heat Exchanger:
Titanium
Manufacturer:
Hayward
Heater Type:
Heat Pump
Warranty:
1-Year Parts-Only Warranty
Top

?     Asked on 3/28/2022by Inyo Visitor

I do not currently have a heater. I have a Hayward Super pump 1 1/2 HP. Can this heater be plumbed into my current system, in other words, my pump runs wide open when on, will this work with this type of heater or do I need a variable speed pump ?
 Reply

A  Answered on 3/28/2022 by InyoPools Product Specialist Craig C.

Hello.  The minimum flow of 30gpm is required to ensure sufficient heat removal from the heat pump condenser, therefore avoiding overheating the unit.  The heat pump is designed for nominal flows of 47gpm through the condenser.  Attached please find a copy of the W3HP31005T Installation & Operations Manual.  Please note the information contained in the Install/Piping Section, page 12.  INSTALLATION & OPERATIONS MANUAL  A pool pump that is rated at or below this heater's minimum flow rate of 30gpm should not be utilized.   Hayward Super Pump Performance Data rates the 1 1/2 HP model at approx. 65gpm with 50 Feet of Head.     
 Reply


?     Asked on 5/12/2022by Marty Rogan

I currently have a Hayward Heat Pump Model # HP21002 and it will no longer hold a freon charge. I'm looking to replace it with this model. My pool has about 32k gallons. It is a 20x40 in ground. Is this model looks compatible to what I currently have. I just want to be sure before i order it.
 Reply

A  Answered on 5/12/2022 by InyoPools Product Specialist Craig C.

Hello Marty.  The Hayward HeatPro Heat Pump, 100K BTU - W3HP31005T is a Heat/Cool unit and is rated 16K BTU less than the Hayward model HP21002.  The reduction in BTUs may result in slightly longer (comparatively) heating cycles.  The W3HP31005T compact design has the same footprint as the HP21002.  If the COOL function is not a priority and the installation site has additional room, you may wish to consider a HEAT only Heat Pump such as the Raypak Classic Series Heat Pump 140,000 BTU - 016033 or the Raypak Classic Series Heat Pump 119,000 BTU - 016015   
 Reply


?     Asked on 2/16/2023by JOE MORENO

i HAVE THE HP31005T WHAT SIZE BREAKER DO I NEED
 Reply

A  Answered on 2/16/2023 by InyoPools Product Specialist Craig C.

Hello Joe.  Attached please find the Hayward HP31005T I/O Manual  Please reference Table 1: Specifications, page 5.   The HP31005T Heat Pump requires a minimum circuit ampacity (amperage) of 37 amps, a recommended breaker size of 40 amps, and a maximum fuse breaker size of 60 amps.
 Reply


?     Asked on 4/14/2025by Inyo Visitor

My pool pump runs on a mechanical timer. Is there an auto shut off for this unit when the pool pump turns off? Do I need to manually turn off the heat pump when pool pump is not running?
 Reply

A  Answered on 4/14/2025 by InyoPools Product Specialist Craig C.

Hello.  Attached please find the IN GROUND POOL/SPA HEAT PUMP HEATERS INSTALLATION & OPERATIONS MANUAL  Please reference Sections - Water Piping - General, page 12, and Water Chemistry - Water Flow Through Heater, page 19.   Water must be flowing through the heater at the minimum rated flow rate during operation.  These heat pumps are designed for nominal water flows of 47 gpm through the condenser.  A minimum of 30 gpm is required.  When the pool pump is Off, the heat pump's internal flow switch is open and does not allow the heat pump to operate.  