By Jandy


Details

Top

Part # 6203-041D

Manufacturer Code 10606405

Alternate Part #'s 10606405, 10606405+, JDY10606405

Product Description

INYO # 6203-041D JANDY # 10606405 GENERAL DESCRIPTION: THIS IS THE COMPLETE HEAT EXCHANGER USED IN THE TELEDYNE / JANDY 400 HEATER THIS INCLUDES THE REAR HEADER AND THE FRONT HEADER USED IN THESE MODELS XE MODELS EG, ES, ES-II, EC SERIES 1 MODELS EPG, EPM, EPC SERIES 2 MODELS ESG, ESC LITE MODELS LLD, LLG, LLC LITE2 MODELS LD, LG, LC, LJ NOTE THAT THE FRONT HEADER IS PART NUMBER R0056400 FOR USE WITH THE 2" FLANGES THE ACTUAL OPENINGS IN THE FRONT HEADER ARE ABOUT 2-1/4" IN DIAMETER SOME MUCH OLDER XE AND SERIES 1 MODELS USED 1-1/2 FLANGES IF THE ORIGINAL HEATER USED 1-1/2" FLANGES, THE FLANGES AND GASKETS WILL NEED TO BE REPLACED ALSO NUMBER OF TUBES: 9 THESE ARE STAGGERED WITH 5 ON BOTTOM AND 4 ON TOP TOTAL LENGTH: 35" (APPROXIMATE - FROM OUTSIDE OF FRONT HEADER TO OUTSIDE OF REAR HEADER) TOTAL HEIGHT: 7-1/4" (APPROXIMATE - THIS IS THE HEIGHT OF THE FRONT HEADER) TUBE BUNDLE LENGTH: 26-3/4" (LENGTH FROM OUTSIDE OF ENDPLATE TO OUTSIDE OF ENDPLATE) TUBE BUNDLE HEIGHT): 3" (END PLATE HEIGHT) WIDTH: 14-1/4" (MEASURED ON THE ENDPLATE - BASICALLY THIS IS HOW LONG THE ENDPLATE IS) ITEMS INCLUDED WITH THE TUBE BUNDLE THE HEAT EXCHANGER ASSEMBLY IS ALREADY COMPLETELY ASSEMBLED WITH THE FOLLOWING ITEMS (1) FRONT HEADER - R0056400, 2" CAST IRON (INCLUDES 3/4" PLUG IN TOP, PRESSURE SWITCH ATTACHMENT FITTING SCREWED IN, AND COMPLETE BYPASS ASSEMBLY, GASKET, AND CAP PRE-INSTALLED) (1) REAR HEADER - R0058300, CAST IRON (INCLUDEDS 3 PRE-INSTALLED BRASS PLUGS, 1 IN TOP AND 2 IN THE END (1) COMPLETE SET OF HEADER GASKETS (18 TOTAL) (1) BAFFLE KIT (8 BAFFLES) (1) BAFFLE RETAINER (8) HEADER NUTS, BOLTS, AND WASHERS (ENOUGH TO MOUNT BOTH HEADERS) SPECIAL NOTE - FLANGES AND FLANGE GASKETS ARE NOT INCLUDED

Top

?     Asked on 9/28/2016by Jose Collazo

i own a Teledyne Laaars and the water comes out rusty, its very old, i used it about two months when i bought the house in 2000 but the house was build in 1998.i am planning to fix it. Do you have a heat exchanger that never rust at all ?
 Reply

A  Answered on 9/29/2016 by InyoPools Product Specialist Scott W.

Unfortunately, don't have a heat exchanger for that model that is more resistant to the chlorine, but RayPak makes a heater with a copper reinforced heat exchanger that is made for saltwater pools. They made these models due to the salt being so corrosive on metals. They are the cupro-nickel models.
 Reply


?     Asked on 1/8/2018by Inyo Visitor

I have a Jandy 399,900 BTU LJ400P heater that was manufactured in 2003, the heat exchanger 10606405 looks like what's in mine, but I need to verify before I can purchase. Are there any other ways to make certain?
 Reply

A  Answered on 1/8/2018 by InyoPools Product Specialist Lennox H.

Hi. This Complete Heat Exchanger Assy - 10606405 is the correct replacement for the LJ400P heater. 
 Reply