By Zodiac
Part # 6200-295
Manufacturer Code R0018105
Dimensions 14.5" L x 27" W x 3" D
INYO # 6200-295 JANDY # R0018105 GENERAL DESCRIPTION: THIS IS THE TUBE BUNDLE USED IN THE TELEDYNE / JANDY 400 HEATER USED IN THESE MODELS XE MODELS EG, ES, ES-II, EC SERIES 1 MODELS EPG, EPM, EPC SERIES 2 MODELS ESG, ESC LITE MODELS LLD, LLG, LLC LITE2 MODELS LD, LG, LC NUMBER OF TUBES: 9 THESE ARE STAGGERED WITH 5 ON BOTTOM AND 4 ON TOP LENGTH: 26-3/4" (LENGTH FROM OUTSIDE OF ENDPLATE TO OUTSIDE OF ENDPLATE) HEIGHT): 3" (END PLATE HEIGHT) WIDTH: 14-1/4" (MEASURED ON THE ENDPLATE - BASICALLY THIS IS HOW LONG THE ENDPLATE IS) MARKINGS: NO MARKINGS ITEMS INCLUDED WITH THE TUBE BUNDLE (1) COMPLETE SET OF HEADER GASKETS (18 TOTAL) (1) BAFFLE KIT (8 BAFFLES) (1) BAFFLE RETAINER (8) HEADER NUTS, BOLTS, AND WASHERS (ENOUGH TO MOUNT BOTH HEADERS)
I have a Model LLD 400N Teledyne Laars Lite pool/spa heater. Serial number A99PG0025. (1) Is Xe 400 the correct heat exchanger, and (2) is the tube bundle Copper or Cupronickel (or some other material more suited to saltwater pools)?
Reply
Hi Al, This is the correct Heat Exchanger for the LLD400N unit. This model does not have a cupro-nickel replacement suitable for saltwater pool only copper.
Reply
I have a Laars Lite 2 Natural Gas Heater is this right Heat Exchanger Part?
Reply
Hi, Don. Yes, this is the correct heat exchanger for the Laar Lite 2 400K BTU unit. If you do not have the 400K then this item will not fit.
Reply
Will this fit the Jandy Lite 2 325P model?
Reply
Hi Mark, This heat exchanger does not fit the Jandy Lite 2 325P you will require this R0018104 (6200-294) Jandy Lite 2 325P Heat Exchanger which we do have in stock ready to ship!
Reply