$24.44

Qty:

Details

Top

Part # 5270-08

Manufacturer Code 628318-307

Dimensions 1-3/4" x 3-1/2"

Alternate Part #'s 17586325, 2443, 2511398-007, 35-125-1125, 449010, 5VR0253, 628318307, RD-25-370, RD25370, SFP37T25H263B, SPG-101-2715

Product Description

Run Capacitor1-3/4"dia x 2-7/8"hgt

Product Specifications

Diameter:
1-3/4 in.
Length:
3-1/2 in.
Top

?     Asked on 1/23/2012by Guest

I need to replace my the capacitor on my 1.5HP pool pump. Do you carry the capacitor I need?
 Reply

A  Answered on 1/23/2012 by InyoPools Product Specialist Patrick P.

Please note that capacitors store an electric charge and should be handled with the utmost caution and care. We do not encourage handling a capacitor without any type of safety measures in place and highly recommend contacting a professional service company for repair/replacement. For those that feel comfortable changing the capacitor here's  >How to replace a pool pump capacitor. In order to match up the capacitor you will need more specifications on the capacitor. You will need to match the voltage, the MFD, whether or not the capacitor is a >run or >start type and the actual dimensions of the capacitor body.
 Reply


?     Asked on 1/23/2016by Tony

The capacitor I'm replacing from a STA-Rite (model XP-1241 120 VAC) pump motor is labeled as such: 20UF/ 330VAC 50HZ. What is a comparable sized capacitor you sell?
 Reply

A  Answered on 1/25/2016 by InyoPools Product Specialist Lennox H.

Hi Tony, The 20MFD 370 Volt Run Capacitor (RD-20-370) will be the correct replacement capacitor.
 Reply


?     Asked on 5/28/2016by Sherry

Hayward Super ll Pump 2HP Capacitator blew out. Gentec 97F9606 25uf +6 50/70Hz 370VAC RD-25-370 do you carry this or is there a correct substitute one. Leslie Pools sold me one & pump only works from 10 min to 1 hr & shuts off overheated ??? Do I need a whole new motor ??
 Reply

A  Answered on 6/4/2016 by InyoPools Product Specialist Lennox H.

Hi Sherry, This capacitor is the correct replacement base off the info you've provided. If the motor is more than 5 years old I would recommend that you replace the entire motor.
 Reply


?     Asked on 8/14/2016by Val

Hi, My 2 HP Hayward SPX1615Z1MNS Maxrate Motor will not start, I can hear humming noise. Could it be the run capacitor problem? Or run capacitor doesn't effect starting the motor?
 Reply

A  Answered on 8/20/2016 by InyoPools Product Specialist Lennox H.

Hi Val, The Run Capacitor does not affect the motor starting just it's running capability. This motor does not have a start switch either so the windings are bad so you will have to replace the entire motor.
 Reply


?     Asked on 8/28/2016by Chuck Lansing

Checked my pool yesterday and found that my capacitor had actual blown up. Is this as simple as just replacing it.
 Reply

A  Answered on 8/30/2016 by InyoPools Product Specialist Alan M.

Yes, Replacing a capacitor is quite easy. You will want to correctly identify and purchase a replacement capacitor from the markings on the shell. Here is a great How to video available on our website, How To Replace a Pool Pump Capacitor.
 Reply


Top
Difficulty

Est. Repair Time

Less than 1 hr

Tools Needed

Screwdriver

1     0

Wrong capacitor.

Written on 10/30/2021 by Guest

My pool attendant changed the capacitor on my old motor about three three times. He thought that the reason the motor would stop after 15 seconds was due to-a faulty capacitor.
He was not aware that capacitors come in all shapes, wastage, purposes and so on. ThenI called INYO after giving them the motor’s specifications, I received the correct capacitor. Unfortunately, the motor had a short, and that was the reason for the failure. Never discard the original capacitor if you have to replace it. The most important information is always printed on the capacitor’s surface. I call the manufacturer and them would not give me any information. Thanks to the agent at INYO I solved the problem.

Were these instructions helpful? 
 

Difficulty

Est. Repair Time

Less than 1 hr

Tools Needed

Screwdriver, Pliers, Socket Set

Pump motor would not run

Written on 10/8/2017 by Guest

Cheched starting and run capacitor.
One was bad
Replaced the bad one but motor still did not run
Need to remove motor so I can inspect motor

Were these instructions helpful? 
 

Top

Review Summary

 (Average 4.8  out of 5 stars)
5 Rating
5 star:
 
(4)
4 star:
 
(1)
3 star:
 
(0)
2 star:
 
(0)
1 star:
 
(0)

The Most Helpful Review


The Most Recent Reviews