$121.10

Qty:

By CompuPool


Details

Top

Part # CPXDISPLAYPCBA

Dimensions 12" x 4-1/4"

Product Description

Display Circuit Board for CompuPool CPX Power Module

Top

?     Asked on 6/2/2015by steve smith

I am getting several different reading on the screen. We get a low salt reading(even though it is not low) with a temp of 69 degrees which can mean a bad circuit board however we are also getting a water fault no water message if the other message is not coming up. The system is about 5 Yeats old and I just replaced the cell last year. Any help or parts to suggest would help. Thanks
 Reply

A  Answered on 6/3/2015 by InyoPools Product Specialist Dennis R.

Steve, Try tightening up the connections that attach to the head of your SCG cell by SLIGHTLY crimping the female ends that attach to the cell posts. If that doesn't work, you probably need a new PCB.
 Reply


?     Asked on 5/21/2016by Inyo Visitor

My compupool screen says POWER OFF. It is not responding when I try and power on. The power is good going to the unit. Any hel will be appreciated.
 Reply

A  Answered on 5/23/2016 by InyoPools Product Specialist Patrick P.

Open up the control unit and check the blue-gray ribbon cable going to the Main CompuPool PC Board. If it or the plug has any burn marks from a possible power surge, you may have to replace the main PC board. If that is not the issue, give Compupool Technical support at 888-989-7258 for further analysis.
 Reply


?     Asked on 5/22/2018by Sonya White

My compu pool display is reading overcurrent and will not produce chlorine,any suggestions?
 Reply

A  Answered on 5/26/2018 by InyoPools Product Specialist Lennox H.

Hi, Sonya. The "overcurrent" message will display when there is an issue caused by a bad Power Circuit Board. Check the connections from the Power Circuit Board to the Display Board.  
 Reply


Top

Review Summary

 (Average 0  out of 5 stars)
0 Rating
5 star:
 
(0)
4 star:
 
(0)
3 star:
 
(0)
2 star:
 
(0)
1 star:
 
(0)