$185.39

Qty:

By Maytronics


Details

Top

Part # 9995862-DIY

Alternate Part #'s MAY9995862-DIY, MAY-201-1025

Product Description

Maytronics 60' DIY Cable with Swivel & Molded Motor Plug

Keep your Dolphin robotic pool cleaner running smoothly with this 60-foot replacement cable, designed for convenience and reliability. This DIY-style cable features a factory-molded plug on the motor end, allowing for quick and simple installation—no retrofit kits or internal wiring required.

Ideal for select Maytronics Dolphin models, this cable includes a swivel to help prevent tangling, a protective rubber spring for durability, and a two-wire connection to ensure consistent power delivery to your cleaner.

Key Features:

  • Length: 60 feet

  • Plug Type: DIY Molded Motor Plug (top-entry)

  • Swivel: Integrated swivel to reduce cable tangling

  • Wiring: 2-wire configuration

  • Spring Type: Rubber protective spring (DIY cables only)

  • Installation: Simple plug-and-play setup – no internal wiring required

Compatible With:

  • Dolphin M200

  • Dolphin Nautilus Plus

  • Dolphin Nautilus CC Plus

Note: This cable is designed for Dolphin models with the top-entry motor port. Please confirm your cleaner model and plug style before ordering. For more details, see our guide: “How to Select the Right Maytronics Dolphin Cleaner Replacement Cable.”

 

Top

?     Asked on 2/25/2016by Katherine Brown

I have a dolphin nautilus PN 99996323. Unfortunately I had a rat that chewed through the blue cable (the cable that runs from the actual cleaner to the power unit). Based on the catalogue there are a few items to choose from. Can you confirm what I need to order please.
 Reply

A  Answered on 2/29/2016 by InyoPools Product Specialist Lennox H.

Hi Katherine, You would have to contact Maytronics at 888.365.7446 with the serial number of your unit and they will provide you with the p/n of the cable you need.
 Reply


?     Asked on 6/10/2018by Hampton

My cable got chewed at the little rubber spring but the long part is fine. Is there a way to buy from the bottom part of the swivel down. The swivel has 2 pins instead of 3
 Reply

A  Answered on 6/10/2018 by InyoPools Product Specialist Lennox H.

Hi, Hampton. You can replace the 3.9' 2 Wire Cable w/Swivel, DIY Plug & Rubber Spring - 9995793-DIY
 Reply


?     Asked on 11/17/2019by Brad

I have disconnected the swivel Assembly and checked continuity for each half (before and after the swivel). When I tested the continuity of the cable from the motor to the swivel, it checks out as good, but I don't have continuity from the swivel back to the control panel. I note that they make the shorter cable from the motor to the swivel, but I don't see a part for the longer cable from the control panel to the swivel. Can you buy that part of the cable without replacing the entire cable?
 Reply

A  Answered on 11/21/2019 by Industry Professional

Can you get us a Model and serial number of the cleaner please
 Reply

  • Commented on 11/21/2019 by Product Owner

    It’s for the Nautilus Plus
     Reply

    • Commented on 12/5/2019 by InyoPools Product Specialist Lennox H.

      Hi, Brad. The  Cable w/Swivel, 2 Wire, 3.9' DIY Plug & Rubber Spring - 9995793-DIY will work for your existing cable. 
       Reply


?     Asked on 7/31/2025by Antonio Borges

Looking for a cable for a Active 10 pool cleaner
 Reply

A  Answered on 7/31/2025 by InyoPools Product Specialist Craig C.

Hello Antonio.  The Active 10 Robotic Cleaner wire cable is Maytronics/Dolphin part 99958902-DIY.  Unfortunately, the 99958902-DIY is currently not available through Inyo Pools.  An Internet search for the 99958902-DIY identified in-stock sources.  Dolphin Active 10 Pool Cleaner Parts
 Reply


Top
Difficulty

Est. Repair Time

Less than 1 hr

Tools Needed

Pliers

Cable was frayed

Written on 8/12/2024 by Guest

I unscrewed the plastic connector, then put the new one on. It was super easy.

Were these instructions helpful? 
 

Difficulty

Est. Repair Time

1 to 2 hrs

Tools Needed

Screwdriver, Pliers, Wrench Set, Adjustable Wrench, Zip-Ties

6     0

Raccoons DESTROYED my Dolphin Nautilus cable!

Written on 2/1/2021 by Guest

1) Begin by removing the impeller grill at the top of the robotic vacuum.
2) Underneath the filter doors, remove all four screws.
3) Carefully lift top portion of housing straight up.
4) Remove the rubber cord boot by pressing it sideways toward the impeller opening. Penetrating oil or WD-40 may be useful.
5) Move the top assembly enough to access the internal cable retainer straps and cable receptacle.
6) Carefully remove both retainer straps.
7) Lift out the neutral buoyancy foam and set aside.
8) Try unscrewing the Nylon retainer nut by hand… carefully use an adjustable wrench if needed.
9) Once the retaining nut has been removed, grasp cable firmly and pull straight up. If corroded, carefully grasp the base of the cable with pliers and pull straight up with slow but increasing force. Receptacle should pop-loose.
10) With the cable removed, feed through the upper housing assembly.
11) *Please note that you will need to re-use your exsisting cable floats.
12) Begin reinstallation by applying pool o-ring lube to the retaining lip for the flexible rubber boot. Then feed cable through upper housing and slide/push boot firmly in place.
13) Also apply lube to the upper portion of the plug and receptacle. Add lube to the round rubber gasket that sandwiched between the Nylon retainer nut and the receptacle.
14) Using firm, even pressure, push straight down on the Nylon retaining nut and begin threading/tightening the nut. (Significant force may be required to squeeze the rubber gasket down and allow the threads to bite.) Once threaded, hand-tighten as far as possible, then very carefully use an adjustable wrench to tighten the Nylon nut a little more. Once the nut shows resistance to turning, STOP.
15) Reinstall cable-retaining straps.
16) Remember to reinstall the foam neutral buoyancy block before reinstalling the top cover assembly.
17) Carefully feed cable, lowering the upper assembly back onto the vacuum body.
18) A second person is useful to help align the pins that fit into the side skirts. With each person guiding/aligning the front side and back side, the top housing assembly should drop straight down onto the vacuum body. Look along the inside lip to ensure all four sides are properly aligned. Do not force. Carefully install screws.
19) Finally, remove the old floats and apply them to the new cable.