Hi Limit Switch - 42001-0063S
Pentair master temp 400 heater. The heater shut down and shows "service heater" light on the display panel, after a few minutes the heater would cycle back on, then off again. The LED on the inside heater panel showed "HLS" (High Limit switch). I replaced the "thermal regulator" and that seemed to fix the problem, now the heater shuts down as before and I get the "HLS" LED diagnostic light again. Any ideas, bad high limit switch? The heater is about 8 years old.
Reply
Hi, Stan. Based on the error code, the High Limit Sensor is bad and will need to be replaced. You can also check the wires or the PCB.
Reply