$741.80

Qty:

By Raypak


Details

Top

Model # 009833

Warranty 1 Year

Dimensions 18-1/4" x 11-1/4"

Alternate Part #'s RAY009833

Product Description

The D-2 Power Vent is a fan-assisted combustion system designed for application to heater models 3366 through 407. When installed as directed, the unit is capable of operating in applications such as through-the-wall venting and reduced horizontal and vertical vent pipe sizes in new and existing installations.

Through-the-Wall Capable
The D-2 Power Vent assembly is a Category III mechanical draft venting system that operates with a positive vent static pressure and with a vent gas temperature that avoids excessive condensate production in the vent. All sizes are capable of relieving flue gases up to a maximum of 100 equivalent feet of vent length. All models have a 4” diameter exhaust connection and can be sidewall terminated using field-supplied cat III-certified vent material. Use the factory-supplied screened elbow as a downturned sidewall vent termination.

Compatible for indoor or outdoor installation
For use with Raypak Digital models sizes 336A - 407A.  The D-2 replaces the standard draft hood.

Certified
The D-2 Power Vent assembly is tested and certified to the latest edition of the American National Standard ANSI Z21.56 for pool heaters.


Multi-Position
Using a field-supplied adjustable 90° elbow, the flue gases may be discharged in any direction (see D-2 Power Vent manual for details). Or simply remove the elbow for vertical venting.


Safety at Its Best
The D-2 Power Vent is equipped with a draft proving switch. This switch ensures that the blower is operating before operating your heater. It is also equipped with a solid state control that allows the blower to purge any residual gas buildup in the heater after the heater has shut down.

 

Features

  • Induced draft
  • Vent (Category III) runs up to 100 ft. equivalent length
  • Plenum sized for appliance capacity
  • Air flow proving switch, mounted and wired
  • Fan motor relay, mounted and wired
  • 90° elbow is used as a termination cap for horizontal venting
  • Heavy-duty galvanized steel cabinet
  • PolyTuf textured powder coat finish
  • Indoor/Outdoor construction
  • Easy installation
  • Limited one-year warranty
  • Shipped loose for field mounting

Product Specifications

Volts:
240 V
Model:
336A-407A
Top

?     Asked on 11/30/2016by dave sample

I wanted to be sure the D2 power vent is what I need for this product. Raypak Heater 407,000 BTU COMM Low NOx ASME NG (009295)
 Reply

A  Answered on 11/30/2016 by InyoPools Product Specialist Adam Y.

Good  afternoon Dave, Yes ,The D2 is the correct vent. It will work with  all Raypak Digital models, sizes 206A - 408.  The D-2 replaces the standard draft hood.
 Reply


?     Asked on 6/19/2019by judy

I have a raypak pool heater indoor and am looking for a power vent for 106 model. I saw one on your website but now can't find it. Cost ? where can I find it?
 Reply

A  Answered on 6/20/2019 by InyoPools Product Specialist Lennox H.

Hi, Judy.  There is not a power vent for the Raypak 106A model, only an Outdoor High Wind Top - 014718. The Raypak 106A cannot be installed indoors. 
 Reply


?     Asked on 5/12/2021by matt

Do you have in stock in your warehouse ratypackd-2 power vent 009833 for 406A heater
 Reply

A  Answered on 5/12/2021 by InyoPools Product Specialist Robert M.

Yes, we currently have the Power Vent 009833 in stock at our warehouse.
 Reply


Top

Review Summary

 (Average 0  out of 5 stars)
0 Rating
5 star:
 
(0)
4 star:
 
(0)
3 star:
 
(0)
2 star:
 
(0)
1 star:
 
(0)