$3,426.15

Qty:

By Raypak


Details

Top

Model # 009218

Warranty 1 Year

Manufacturer Code P-R336A-EN-C #50

Alternate Part #'s 009218, P-R336A-EN-C #50, PR336AENC, RAY009218

Product Description

Think about being able to use your pool or spa at the perfect comfort level even when Fall arrives...or when the first chill of Winter is felt in the wind...or in the Spring or Summer when evenings can turn chilly in a minute!  Helping you get more enjoyment from your pool or spa is the smart idea behind the Raypak heaters.

BENEFITS:

  • Digital control with liquid crystal display (LCD) for temperature selection and heater settings

  • Capron resin headers prevent rust stains from harming pool surface

  • Plumb directly from provided 2" PVC threaded union

  • Smart microprocessor controls diagnostic read-out and continuously monitors operating status

  • Completely field serviceable

  • Small footprint

  • High efficiency

  • Guaranteed high wind reliability

  • Looks smart and works smart

  • Thermal Efficiency of 83% 

  • 1 Year Warranty

Elevation: 0 Ft. – 2000 Ft. Click Here for High Altitude Pool Heaters

    

California Customers Please Note:  South Coast Air Quality Management District (SCAQMD) Area of Jurisdiction REQUIRES a Low Nox Heater be installed.  The following 6 California Counties are affected:  Los Angeles, San Bernardino, Ventura, Orange, Riverside, & Kern. Installing a non-compliant heater in these counties will void the manufacturer's warranty and could result in a fine from your local code enforcement.    

Click here for RayPak Low Nox Heaters

Dimensions:

Raypak Pool Heater DimensionsRaypak Pool Heater Dimensions

Raypak Heater Dimensions

Warranty:

WARRANTY EXCLUSIONS 
This Limited Warranty does NOT apply; 
1. if the product has been moved from its original place of installation, or if the original 
owner no longer owns the property where the original installation was made; 
2. if the product is not properly installed with a pool or spa by a qualified licensed installer in 
accordance with applicable local codes and ordinances, good trade practices, and the 
manufacturer’s installation instructions; 
3. if the rating plate(s) or serial number(s) are altered or removed; 
4. if the product is modified in any way, or non-factory authorized accessories or other 
components are used in conjunction with the product; 
5. to damage, malfunctions or failures resulting from failure to properly install, operate or 
maintain the product in accordance with the manufacturer’s instructions; 
6. to damage, malfunctions or failures from abuse, act of nature, accident, fire, flood, freeze, 
lightning or the like; 
7. to damage, malfunctions or failures resulting from [or due to] connected system control 
devices; 
8. performance problems caused by improper sizing of the heater or electric service 
voltage, wiring or fusing; 
9. use of any attachment, including any energy saving device not authorized by the 
manufacturer. 
10. to damage, malfunctions or failures from misuse or neglect, including but not limited to, 
freeze-ups, operating the heater with the cabinet door off, having flow restrictions or 
obstructions between the heater outlet and the pool/spa, or not maintaining a proper 
chemical balance (PH level must be between 7.4 and 7.8 and total alkalinity between 100 
and 150 PPM. Total dissolved solids (TDS) must be no greater than 3000 PPM)

Product Specifications

BTU:
336,000 BTU
Ignition:
Electronic
Digital Readout:
Yes
Elevation:
0-2,000 ft.
Heat Exchanger:
Copper
Heater Type:
Natural Gas
Manufacturer:
Raypak
Top

?     Asked on 1/16/2012by Guest

Will a gas heater operate at the low speed of a dual speed motor?
 Reply

A  Answered on 1/16/2012 by InyoPools Product Specialist Patrick P.

Probably not - Most gas heater will shut off at low GPM levels (20-40) to keep the heater cores from overheating - 20 for 200 BTUs, 40 for 400 BTUs. Depending on your pool system you might get these GPM levels at the low speed but generally these heaters must be run at the motor's high speed.
 Reply


?     Asked on 10/10/2012by Guest

What is the difference between an Electronic and Millivolt ignition?
 Reply

A  Answered on 10/10/2012 by InyoPools Product Specialist Patrick P.

The basic answer is that Millivolt is the old style of ignition, using a standing pilot light. While the electronic ignition uses a spark start system like a gas grill. Electronic ignitions are more efficient in gas usage and also are better suited for high wind areas where a pilot light might get extinguished.
 Reply


?     Asked on 8/30/2013by Guest

What is the amp draw for RayPak RP series digital display?
 Reply

A  Answered on 8/30/2013 by InyoPools Product Specialist Patrick P.

The RP series draw 4 amps on 120 volts and 2 amps on 240 voltage.
 Reply


?     Asked on 9/30/2014by Guest

What is involved with electrical hookup?
 Reply

A  Answered on 9/30/2014 by InyoPools Product Specialist Patrick P.

We can get you the instructions for the installation, but to keep the heater under warranty you would have to have it installed by a licensed electrician.
 Reply


?     Asked on 11/6/2014by Paul Flickinger

How long would it take to get this item?
 Reply

A  Answered on 11/7/2014 by InyoPools Product Specialist Robert M.

Hello Paul - The delivery time would be 7-10 business days.
 Reply


Top
Difficulty

Est. Repair Time

1 to 2 hrs

Tools Needed

had installed professionally

1     0

huge pool, bad advise from pools guys on how to heat and not to heat!

Written on 4/26/2022 by Guest

actually my success story is that I did my own reaseach then called a close friend who buys from INYO and highly recommended them. So, after talking at lenghth with the INYO rep, he answered all my questions and educated me about other fact concerning these products I was buying. He was thorough, informative, extremely polite and personable! The process was easy! The delivery was sooner than I expected and came off without a hitch! Will definatly use INYO pools for all my pool needs! Thank you guys, you are awesome!

Were these instructions helpful? 
 

Difficulty

Est. Repair Time

4 to 8 hrs

Tools Needed

Screwdriver, Nut Drivers, Pliers, Socket Set, Wrench Set, Adjustable Wrench, Pipe Wrench

No Issues, but the unit is heavy.

Written on 3/21/2021 by Guest

Removed old 400lbs pool heater.
Cleaned concrete pool equipment pad.
Installed pool heater on pad (its 300lbs or so. Two person job with an appliance dollie).
Wired unit for 220v. (it will accept 120v or 220v 3wire or 4 wire)
Plumbed natural gas and added a t-trap. Tested gas lines and fittings for leaks with soapy water.
Plumbed in pvc water lines.
Lubed water head orings with pool lubed, and snugged down the supplied quick disconnect unions.

Took $90 or so in additional pvc unions, gas line and gas fittings, gas line sealer, pvc primer and glue.
Four trips to the home improvement store.

Removal of old pool heater, Install time with trips to the store, about 5 or 6 hours on a Saturday afternoon.

Fired up the heater and enjoyed a 101 degree night in the spa.
This pool heater is so quiet compared to my old Larrs.

Were these instructions helpful? 
 

Difficulty

Est. Repair Time

2 to 4 hrs

Tools Needed

Screwdriver, Pliers, Socket Set, Wrench Set

Old 15 year old ray pak died

Written on 8/23/2020 by Guest

Replaced heater with new similar size Raypak. Water temp rose 15 degrees within a day. Now my swim is relaxing.

Were these instructions helpful? 
 

Difficulty

Est. Repair Time

1 to 2 hrs

Tools Needed

Screwdriver, Adjustable Wrench

1     0

Fed up with Jandy equipment and heater repairs

Written on 4/24/2020 by Guest

I spent $100 here and there on replacement parts for my Jandy LXi400. It started firing up but cut out. I could not find the issue. I was not about to spend hundreds on a service call.

I read about heaters. I was impressed by Raypak reviews and standards. I am a little annoyed about there being no warranty for a self install - I mean why unless any fault is caused by the install!

Anyway. The delivery driver, although curbside delivery, helped me take it to the pool shed. Next day, I simply attached the half inch gas pipe (I had to buy a 2 foot piece since the gas valve is set farther back than Jandy) and wired TWO wires into the power of my Jandy aqualink power unit - its a dream.

It took about an hour. SOOO much better. Water heats great. Works with my Jandy remote. No issues at all. I love it. I have, and will continue to recommend both Raypak and Inyo.

Were these instructions helpful? 
 

Difficulty

Est. Repair Time

Less than 1 hr

Tools Needed

Don't know. My son installed it

My raypak heater was not repairable. The entire bottom was rusted out

Written on 6/21/2018 by Guest

I called customer service and ordered a replacement. Customer service rep was courteous and the transaction was quick. You can't beat their prices with free shipping it was $700 cheaper than a quote from a local pool store! Shipping was quick too. Hook it right up with minimal effort and we're good to go. Thank you INYOPools!!!

Were these instructions helpful? 
 

Difficulty

Est. Repair Time

2 to 4 hrs

Tools Needed

Screwdriver, Socket Set, Adjustable Wrench

4     0

17 yr. Old Raypak heater stopped working.

Written on 5/3/2017 by Guest

Ordered the same sized raypack from inyo pools at a great price. The size and hookups were the same as the old one so no new plumbing was necessary. My biggest concern was that the company warranty would not be allowed unless installation was done by a licensed contractor. Since the heaters were basically identical, I decided to do it myself. Out with the old, in with the new. Took pictures of the old electrical hookups and installation was easy. New O- rings and the plumbing was done. Everything matched up perfectly. Opened the pool the next day and crossed my fingers when I turned on the heater. Two sparks and it kicked right in.
The price was 300.00 less than any other pool stores for the same unit and installation by a dealer would have been an additional 300.00 or more. I just opened my pool this year (2nd for the heater) and it kicked in after cleaning out the gas tube. It seems spiders build webs over the winter and sometimes prevent gas from flowing. Cleaned the line and heater kicked in. Very happy.

Were these instructions helpful? 
 

Top

Review Summary

 (Average 4.95  out of 5 stars)
18 Rating
5 star:
 
(17)
4 star:
 
(1)
3 star:
 
(0)
2 star:
 
(0)
1 star:
 
(0)

The Most Helpful Review