Part # SP071621
Dimensions 9" L x 9.5" W x 15" D
Hayward® SP071621 Multiport Valve – OEM Replacement
For Hayward® Vari-Flo XL Top-Mount Sand Filters
The Hayward® SP071621 Vari-Flo® multiport control valve delivers dependable performance and superior flow for efficient filtration, backwashing, rinsing, and other essential functions. Built from high-strength materials and factory-tested for quality, this OEM valve ensures long-lasting reliability for your Hayward® sand filter system.
⚠️ Note: Clamp and O-ring are not included with this valve.
✅ Key Features:
✅ Genuine Hayward® OEM replacement part
✅ 6-position lever-action handle for easy operation
✅ Integral sight glass for clear backwash viewing
✅ Engineered for maximum flow and minimal pressure drop
✅ 1-year limited manufacturer warranty
➡️ Functions & Settings:
Filter – Standard operation and vacuuming
Backwash – Cleans sand bed of debris
Rinse – Final flush after backwash
Waste – Bypasses filter for draining
Recirculate – Circulates without filtration
Closed – Shuts off water flow
Winter – Winterizing position (SP0714T only)
⚠️ Compatibility:
Fits Hayward® Pro Series top-mount sand filters using SP071621 or SP071113 valves
Does not include clamp or O-ring – sold separately
✅ Keep your sand filter performing like new — order the genuine Hayward® SP071621 valve today for proven OEM quality and reliability.
How do I bleed air for a top mounted Hayward multiport valve? They have no air bleeder valve.
Reply
Hayward TOP mounted multiport valves do not require an air bleeder valve. They self purge air in the system through the return lines.
Reply
Can we get this valve (Hayward Var-flow sp071621) to replace ours. The old conections are straight up and down, will this pose a problem ?
Reply
Hi Jill, If you can provide us with the manufacturer and model of the filter you have we can confirm if the valve will replace the one that you have.
Reply
I have an Hayward Vari-flo xl Valve (75 pgm/284 lpm) filter and I have a leak at the pressure gauge. Do I have to have a specific pressure gauge or will any work? I guess that's my problem since its leaking from it
Reply
Hi, The standard 1/4" NPT Back Mount (102D-204D) or Bottom Mount (101D-204D) pressure gauge can be used with this valve.
Reply
Can I use this valve to replace an SP0714T with 1.5" fittings. Our pump is 2" and I'd like to avoid the reduction if possible.
Reply
Hello Richard, Yes you can swap the SP0714T to the SP071621, but the questions would be are you using adaptors to fit into your 2" lines from your SP0714T? Just make sure you have 2" all the way around to make sure this will work for you.