How To Replace an AutoPilot Salt Cell

WRITTEN BY: 

  3.33 out of 5 stars on 9 ratings
(Click on a star to add your rating)

A salt chlorine generator cell will last about 3 -5 years before it has to be replaced. The following guide describes how to replace an AutoPilot Salt Cell.

Things You'll Need

Step by Step

Top

Step 1

The first step in replacing the Turbo Cell is to turn off the power to the pump and Chlorine Salt Generator. Ideally this should be done at the circuit breaker. The controller display should go blank.

Step 2

Open the air relief valve located on top of the pool filter. This will release the pressure from the system and make it easier to remove the cell.

Step 3

Unplug the cell cord from the AutoPilot salt cell.

Step 4

Unscrew the two unions on the salt cell. We recommend using a strap wrench or large channel locks if the unions cannot be removed by hand.

Step 5

Remove the Auto Pilot salt cell from the manifold.

Step 6

Place the new salt cell onto the manifold. The cell can be placed on the manifold in any position. There is no up or down direction for the cell.

Step 7

Tighten the two unions. This can be done by hand. The unions do not need to be overtightened with a wrench.

Step 8

Plug the cell cord back onto the AutoPilot salt cell.

Step 9

Turn power back on to the pool pump and salt chlorine generator. The controller should light up and the pool pump should operate.

Step 10

Any air in the piping should be coming out of the open relief valve. When water starts to spray out of the relief valve, shut the valve off.

Step 11

After a couple minutes the AutoPilot control box should display the output level, time, and temperature.

Comments

Top
(1 to 11 of 11)

 Posted: 12/8/2021 

How do I get the old cell cable off the nano pilot, I tried to pull it out but it won't unplug.
 Reply

InyoPools Product Specialist  Posted: 12/9/2021 

There is no trick or tab to press to release an AutoPilot cell. You can see in this picture, there are just three holes for the prongs to insert, no catches or clips. It may be stubborn due to grime, corrosion, or it's just old.
 Reply

 Posted: 12/11/2021 

Thank you for your response..
 Reply

InyoPools Product Specialist  Posted: 9/4/2017 

Golfnmike - See Page 17 of Hayward's Aqua Rite Diagnostics Manual. If these steps do not solve your problem, give Hayward a call at 866-772-1200 and talk to their tech staff.
 Reply

 Posted: 9/1/2017 

I just replaced my Hayward Cell (T-15) but my Aqua Rite control panel is stating I need to check salt and inspect cell??
 Reply

InyoPools Product Specialist  Posted: 6/4/2017 

rwellesp - The new cell should show output in 1-2 minutes. Try spraying contact cleaner into the plug. Let it dry, then put the plug back onto the cell. Make sure it is on all the way.
 Reply

 Posted: 6/2/2017 

how long before the new cell shows output. My auto pilot Nano system says warning: no output!
 Reply

InyoPools Product Specialist  Posted: 8/6/2015 

Gato - The power coming out of the Control Box has been converted from AC to DC. DC power can only be plugged into the cell one way. It cannot be reversed.
 Reply

 Posted: 8/5/2015 

The cell cord connection to the manifold has two prongs (a third one is not use and plugged on the cord). Do I have to orient the plugs correctly as if each prong has a different voltage? It seems to work in either position.
 Reply

InyoPools Product Specialist  Posted: 4/18/2015 

power cord - No. You generally do not have to replace the power cord unless it is defective.
 Reply

Anonymous  Posted: 4/16/2015 

do you need to replace the power cord as well???
 Reply