Step 2
VALVE INSTALLATION - When installing these 3 way diverter valves, you have to watch how they are positioned. These valve have three ports: two ends and one center. By design you can close off part of all of the water flow from either end ports, but you cannot shut off the center port. The handle will only rotate 180° on the side away opposite the center port. If this valve is installed incorrectly, as shown later, it is possible to inadvertantly shut off all water to the pump and run it dry. In this setup Valve 1 selects the flow from either the pool drain or the skimmer or both. Valve 2 selects the flow from the pool vacuum line or Valve 1.or both.
InyoPools Product Specialist Dennis R. Posted: 11/27/2014
crossan - Sounds like you have three ball valves that work independently on each of three lines: one to the skimmer; one to the main drain; and one to the suction port. Shutting one off has no effect on the other lines. In this case I would leave the main drain and the skimmer open for normal operation. When you want to use the cleaner, open the suction port. If you have limited suction, you may have to partially close the main drain or skimmer line while you are using the cleaner.Reply
crossan Posted: 11/25/2014