Product Description

Pureline Replacement Flow Switch, Compatible with AquaRite® Flow Switch w/ 2" Tee & 15' Cable - PL7102

The switch can be removed from the tee if that is all you need to replace.

Used with the following Systems:

  • Goldline®/Hayward®
    • AquaRite®, AquaLogic®, ProLogic®,
  • PureLine®
    • Crystal Pure

 

Disclaimer:

All manufacturers’ names, brand names, trademarks, images, symbols, descriptions, and part numbers are used herein for reference purposes only.

Product Specifications

Manufacturer:
Pureline
Top

?     Asked on 12/30/2014by keith edwards

Can you send me instructions on how to install The Hayward GLX-FLO flow switch?
 Reply

A  Answered on 12/31/2014 by InyoPools Product Specialist Robert M.

Hello Keith - Click Here for instructions on how to install the Hayward flow switch.
 Reply


?     Asked on 6/25/2016by William Gleason

is it possible to just buy the connector piece that plugs into the mother board? I am getting a no flow indicator and I have just replaced the salt cell and mother board. Pretty sure my flow sensor is ok - but the connection is not.
 Reply

A  Answered on 7/2/2016 by InyoPools Product Specialist Lennox H.

Hi, The connect is not sold separately, you will have to replace the entire flow switch.
 Reply


?     Asked on 4/9/2017by A. Craig

I am getting a check cell reading, which when I pulled the cell off for cleaning, I noticed a turquoise film on the end where the copper switch was housed. After cleaning the cell and wiping off the turquoise residue, I reinstalled the cell. The check light went out but now 3 days later it is back on. Has anyone else had the turquoise residue? Is it time for a new switch? Thank you.
 Reply

A  Answered on 4/11/2017 by InyoPools Product Specialist Scott W.

Yes, sounds like it's time for a new flow switch.
 Reply


?     Asked on 5/25/2018by Ed

My aquarite was showing a salt reading of 1900 last weekend. I added 40 lbs of salt. Several days later the reading was 2200. I added another 40 lbs of salt. Now several days later the reading has dropped to 2100. My pool is just under 15,000 gallons and typically one 40 lb bag of salt would increase the level by about 400 ppm. Does the flow control switch capture the ppm and possibly need replaced? Or could this be a board issue?
 Reply

A  Answered on 5/25/2018 by InyoPools Product Specialist Lennox H.

Hi, Ed. The flow switch does not relay the salt level to the controller, the cell does. You may need to have the cell tested at a Hayward Repair Center to make sure it's working.
 Reply


?     Asked on 3/18/2019by Brian

My Hayward Aqua Rite salt system shows a flashing light "no flow" on the control panel. There is significant flow from the pump through the filter then to the salt cell and out to the pool. The display shows the cell is generating at 3000. The flow switch is located before the salt cell but without 12" of strait pipe between the filter and the flow switch. What should I do? Can the salt cell be oriented in either direction or is there a direction of flow required? Thanks
 Reply

A  Answered on 3/22/2019 by InyoPools Product Specialist Lennox H.

Hi, Brian. Use the steps on page 26-30 of the AquaRite Troubleshooting Guide. The Flow Switch - GLX-FLO-RP may need to be replaced.  The call can be installed in any orientation. 
 Reply