Picking the right Intermatic Pool Timer can be a little overwhelming when review all their options. In this guide, we hope to narrow down your field of choices and explain the important stats to check
Ratings to Check
if you’ve seen a Intermatic catalog, you will know how many different acronyms, ratings, and specifications are tagged on each one of these pool timers.So, to cut out the confusion let’s focus on the key things you should check
Voltage
Refers to the circuit voltage required to operate the timer mechanism and that can be dispensed / controlled by the pool timer. Residential pool pumps are wired with either 110V or 220V, for most mechanical timers, you’ll need to know the specific voltage your pump is wired for, to pick a compatible timer. most digital pool timer listed below are dual voltage, meaning they can be wired to 110V or 220V.
not sure on which voltage your poo pump motor runs on? rRead these guides to learn how to measure circuit voltage, Is My Pool Pump 115 V or 230 V, How To Use a Multimeter to Test a Pool Pump Motor – Voltage
Max Load Amps
This rating defines the pool timer’s circuit capacity. The simplest explanation I’ve heard to explain amperage, is that the voltage is the straw, the amps are the juice that delivers the energy from the juicebox, I mean breaker box.
Residential pumps are wired for 110V or 220V but their amp draw varies according to the pump’s horsepower. For the UST1102 1 HP Century pump motor pulls 15 A on a 115 V circuit; whereas a UST1152 1.5HP Century pump motor puuls 18.6 A on the same 115 V circuit.
if you plan to wire muliple devices to an Intermatic Pool Timer, you’ll need to ttally up how many ampsto make certain it does not exceed the timer’s Max Amp Load.
Freeze Protection
Freeze protection devices are pool automation controls with built-in thermostats; they monitor air temps and will turn on the pump if temperatures drop below a set point. Flowing water is less likely to freeze and burst your pvc plumbing then if it was left o to settle. Freeze protection devices can go a long way in preventing a costly replumbing repair.
Freeze protection devices come with some timer packages, are available as accessory add-ons, or standlalone freeze protection devices
Pool owners living in cold states or in areas subject to freezing cold fronts (Texas, I’m looking at you) freeze protection timers are a great addition. if you’re in persistently cold states like Michigan, Minnesota, the Dakotas and the like, it’d be best to fully winterize and drain your pool and its plumbing.
Heater Protection
Commonly referred to as a fireman’s switch, a timer’s heater protection feature turns off the heater about 20-minutes before the pump is scheduled to turn off. By shutting down the pool heater before the pump, the heat exchanger is allowed to cool down gradually. Fireman switches were required on older gas pool heater models because they heater cabinets did not dissipate heat fast enough.
Plug Type, Above Ground Pool Timer Specific
Single Speed Pump, 110 Volt
Model Number | Enclosure Type | Voltage | Max Load | Heater Protection* |
---|---|---|---|---|
T101P3 | Plastic | 110 VAC | 40 A | No |
T101R3 | Metal | 110 VAC | 40 A | No |
P1251P | Plastic | 110 VAC | 40 A | No |
T101P201 | Plastic | 110 VAC | 40 A | Yes |
T101R201 | Metal | 110 VAC | 40 A | Yes |
Single Speed or Dual Speed, 220 Volt
Model Number | Enclosure Type | Voltage | Max Load | Heater Protection | Dual Speed Pump Control |
---|---|---|---|---|---|
T104P3 | Plastic | 220 VAC | 40 A | No | On / Off Only |
T104R3 | Metal | 220 VAC | 40 A | No | On / Off Only |
T104P201 | Plastic | 220 VAC | 40 A | Yes | On / Off Only |
T104R201 | Metal | 220 VAC | 40 A | Yes | On / Off Only |
T10604R | Metal | 220 VAC | 40 A | No | On / Off & Hi / Lo |
Above Ground Pool Timers
Model Number | Voltage | Max Load | Plug Type | Cord Length |
---|---|---|---|---|
P1101 | 120 VAC | 15 Amps | Standard 3-Prong | 22 inch |
P1121 | 120 VAC | 15 Amps | Standard 3-Prong | 13 inch |
P1131 | 120 VAC | 15 Amps | Twist Lock | 22 inch |
Digital Pool Timers
Model Number | Enclosure Type | Voltage | Max Load | Freeze Protection | Heater Protection | Remote Included | Two Speed Motor Control |
---|---|---|---|---|---|---|---|
PE153P | Plastic | 120 /2 40 VAC | 17 A | No | No | No | Yes |
PE153F | Metal | 120 / 240 VAC | 17 A | Yes | No | No | Yes |
PE153PF | Plastic | 120 / 240 VAC | 17 A | Yes | No | No | Yes |
PE653RC | Metal | 120 / 240 VAC | Circuit 1 = 20 A Circuit 2-5 = 15 A* | Yes | No | Yes | Yes |
Freeze Protectors
Model Number | Enclosure Type | Voltage | Includes Timer | Thermostat Range |
---|---|---|---|---|
PF1102 | Metal | 240 VAC | No | 33°F – 42°F |
PF1103 | Metal | 120 / 240 VAC | No | 33°F – 42°F |
PF1102T | Metal | 240 VAC | Yes | 33°F – 42°F |
PF1103T | Metal | 120 / 240 VAC | Yes | 33°F – 42°F |
PF1222TB | Metal | 120 / 240 VAC | Yes | 33°F – 42°F |
Do you have any questions about Intermatic pool timers or swimming pools in general, feel free to leave a comment down below, or visit us over at InyoPools.com
Great. So what one do I need.
What do you need to control?
I need a replacement timer part for my PF122TB. The right side timer/motor has stopped functioning.