?     Asked on 11/25/2019by Charles Pudwill

I just purchased a new motor for my Hayward Super Pump from your company. It's running great with plenty of pressure at my hot tub jets. When I turn on my Raypak 266 BTU heater (Installed in 2006), I get a "Clean Strainer/Filter", then "PRS" fault and "Low Pressure" error codes. We're in S. FL and haven't used it since last winter so ... It's most likely the pressure relief valve? Can they become stuck and be trouble shot or is this a normal replacement issue? Thanks for the help!!
 Reply

A  Answered on 11/25/2019 by InyoPools Product Specialist Lennox H.

Hi, Charles. The issue sounds like a faulty Water Pressure Switch - 006737F.