$582.71

Qty:

By Hayward Pool Products


Details

Top

Part # 6220-210

Manufacturer Code IDXLBWR1930

Dimensions 9" L x 10" W x 8.5" D

Alternate Part #'s 1503001801, IDXLBWR1930, 47-150-2020, HAYIDXLBWR1930, HPPIDXLBWR1930

Product Description

Combustion Blower H-series Low Nox 240V - IDXLBWR1930

Top

?     Asked on 6/4/2015by M G Canavan

When my heater is and heats up, after 5 or 10 min., it begins making a banging sound. It is an H400. Can you advise why this happening?
 Reply

A  Answered on 6/4/2015 by InyoPools Product Specialist Brian M.

If you have an external by-pass it needs to be closed. This will be a valve between the pipes in and out of the heater. When you close it, it forces water through the heater. When it is open no water goes through the heater. So the water in the heater boils and turns to steam. With no where to go it starts banging and jumping.If you close this valve or it is closed and you still have trouble the internal by-pass has gone bad. The overheating from the first problem will often cause this. You remove the water header from the side of the heater and pull the pipes from it. In reality you will probably have to pull the gas pipe so you can move the heater from the pipes. You will find the assembly inside the manifold. It will probably come out in pieces but the new one goes back in as a unit. This will regulate your water flow and keep it heating at a constant temp.
 Reply


?     Asked on 10/8/2018by tim

will this blower motor work on the old model hayward heater model# H400IDL
 Reply

A  Answered on 10/9/2018 by InyoPools Product Specialist Hector F.

Yes, this does show as a compatible combustion blower for your model heater. 
 Reply


?     Asked on 7/28/2019by John Otten

Will this blower work with a H250IDL?

 Reply

A  Answered on 7/31/2019 by Industry Professional

This will fit that heater, please make sure your current blower voltage is 220V
 Reply


A  Answered on 7/31/2019 by Industry Professional

Yes, that is the correct Combustion Blower H-series Low Nox 240V - IDXLBWR1930.
 Reply


?     Asked on 7/29/2019by John Otten

Will this blower work with a Hayward pool heater model number: H250IDL?

 Reply

A  Answered on 7/31/2019 by InyoPools Product Specialist Matt S.

Yes, the IDXLBWR1930 Combustion Blower is the correct replacement for the H250IDL.
 Reply


?     Asked on 6/7/2020by Anthony

will this Blower work for my hayward H400IDL2 thanks
 Reply

A  Answered on 6/8/2020 by InyoPools Product Specialist Hector F.

Yes, this blower model is compatible with the Hayward H-Series Low NOx - IDL2 heater series. 
 Reply


Top
Difficulty

Est. Repair Time

1 to 2 hrs

Tools Needed

Screwdriver, Nut Drivers, Socket Set, Adjustable Wrench

AO Error on heater - Fan not coming up to full speed.

Written on 3/30/2023 by Guest

Easy replacement.
Isolate power to heater.
Remove top cover of heater unit for access.
Disconnect power connector to fan.
Remove both vacuum lines.
Remove hex screws.
Remove old fan assembly.
Install provided insulation at the inlet and outlet of replacement fan assembly
Place new fan and install hex screws.
Install vacuum hoses.
Connect power connector.
Turn on power to heater.

Ready to rock!