$310.00

Qty:

By Century Motors


Details

Top

Part # UQC1102

Warranty 1 Year

Alternate Part #'s 11801, EUQC1102, K48K2PA101, K48K2PA101A2, K48K2PA105, K48K2PA105C1, UQC1102, CRMUQC1102

Product Description

Voltage 115/230, Max Amps 115V = 12.6 230V = 6.3, Single Speed, Square Flange, RPM = 3450, Threaded Shaft, Frame = 48Y Used on the following models: Sta-Rite Max-E-Glas, Max-E-Glas II, Dura-Glas, Dura-Glas II, Dyna-Glas, Dyna-Max Pentair Whisperflow, Pinnacle and Anthony AR2 Series.

Note: NOT California Title 20 Compliant. 

California Title 20 Compliant Options:

Motor Dimensions Motor Dimensions
Motor Image Motor Image

Product Specifications

HP:
1 HP
Frame:
48Y
Volts:
115/230 V
Speed:
Single
Amps:
12.6/6.3 amp
Service Factor:
1.25
Total HP:
1.25 HP
Manufacturer:
Century (A.O. Smith)
Shaft:
Threaded
Flange:
Square
RPM:
3450 RPM
Phase:
Single
Commonly Used On:
Sta-Rite Max-E-Glas, Max-E-Glas II, Dura-Glas, Dura-Glas II, Dyna-Glas, Dyna-Max Pentair Whisperflow, Pinnacle and Anthony AR2 Series
Top

?     Asked on 1/11/2012by Guest

What is Service Factor?
 Reply

A  Answered on 1/11/2012 by InyoPools Product Specialist Patrick P.

Service Factor(SF) is a multiplier that when multiplied by the horsepower of the motor indicates the total permissible horsepower loading that may be carried when the motor is operating at rated voltage and frequency. The most important thing to remember when replacing a motor is that the replacement motor's horsepower times its service factor must be equal to or greater than the original motor's horsepower times its service factor. The Service Factor rating can be found on the motor label. See Step 4 of our How to Read a Pool Motor Label guide.
 Reply


?     Asked on 1/12/2012by Guest

Why do I need to purchase a new shaft seal?
 Reply

A  Answered on 1/12/2012 by InyoPools Product Specialist Patrick P.

We strongly recommend replacing the shaft seal. The purpose of a shaft seal is to prevent water from running down the shaft of the motor and into the motor housing. Water will damage the bearings and cause the motor to fail. A new shaft seal should be installed whenever a motor is replaced. The motor manufacturer can deny the warranty if the motor fails to due to water damage from a faulty shaft seal. To find your shaft seal you will need to visit our Pool Pump Parts Page or the Spa Pump Parts Page and select your make and model.
 Reply


?     Asked on 1/12/2012by Guest

Why should I purchase a Tune Up Kit?
 Reply

A  Answered on 1/12/2012 by InyoPools Product Specialist Patrick P.

A Tune Up Kit includes all of the essential replacement seals and gaskets for the pump. The seals and gaskets should be replaced when installing a new motor on your pump. New seals will prevent the pump from leaking water or losing the prime. A Tune Up Kit will protect your motor and ensure that the pump is working efficiently.
 Reply


?     Asked on 1/11/2015by kenneth garcia

Is the UQC1102 the correct replacement motor for Sta-rite model k48k2pa105c1 1hp Max-E-Glas?
 Reply

A  Answered on 1/12/2015 by InyoPools Product Specialist Robert M.

Hello Kenneth - The UQC1102 would be the correct replacement motor for the K48K2PA105C1 1HP Max-E-Glas.
 Reply


?     Asked on 2/28/2015by Chet

Is the UQC1102 the right motor for a Sta Rite model P2RA5F-182L pump and if so, which tune up kit should I buy with the motor? If not, then which motor and tune up kit would be correct?
 Reply

A  Answered on 3/2/2015 by InyoPools Product Specialist Robert M.

Hello Chet - The correct replacement motor for the P2RA5F-182L is the UQC1152. The tune up kit for Dura-Glas models manufactured before 1998 is GOKIT6. The tune up kit for models manufactured since 1998 is GOKIT54. If your seal plate has a copper cone it is pre 1998. If it does not, you have a 1998-current model.
 Reply


Top
Difficulty

Est. Repair Time

More than 8 hrs

Tools Needed

Screwdriver, Socket Set, Wrench Set, Adjustable Wrench

Seal Allowed Water into Motor

Written on 4/30/2019 by Guest

Removed pump seal plate and motor. I also needed new seal plate so simply purchased diffuser - c1-200PA, impeller - C105-138PEB, Trap cover O-ring, 5056-15; Motor - UQC1102, and tune-up kit - GOKIT54. Assembled the parts and boom, you have it

Were these instructions helpful? 
 

Difficulty

Est. Repair Time

1 to 2 hrs

Tools Needed

Screwdriver, Pliers, Socket Set

1     0

Bearings in Pump Motor Went Out. Motor Began to Grind Loudly

Written on 3/23/2019 by Guest

Bearings went out. The motor began to grind loudly. I checked the numbers on the motor and ordered a replacement from INYO Pools. They had a perfect match. To replace it I turned off the breaker, removed the motor from the pump.

Stood it on end to pull the electrical cover and remove the three wires. Pulled them out and moved the new motor into the place where the wires could be connected. Two reds and a green went right into place. Put the cover back on the wires and attached the motor to the pump.

While the motor was off and the pump apart, I replaced the o-rings that INYO supplies as a kit. The new motor was quieter than the original ever was. This was an easy DIY, it just looks daunting. I'm not an electrician or mechanic.

Were these instructions helpful? 
 