This guide will show you how to replace a Hayward AquaRite Salt Cell. A salt chlorine generator cell will last about 4 -5 years before it has to be replaced. This guide describes how to replace a GLX-Cell-15-W Turbo Cell in a Aqua-Rite Electronic Chlorine Generator. If you are replacing an existing GLX-Cell-15-W chlorinator cell, as we are showing here, no re-configuration of the digital controller is necessary. Note: Earlier versions of this cell were identified as T-Cell-15.
Click here to view the Aquarite Turbo Cells.
EDWARD L MCCRAE Posted: 10/11/2021
I have AquqRite chlorinator with t-15 cell. The cord from cell to control panel has been chewed thru cutting wires in multiple places.Is it possible to repair/replace cord? If so is there a wirig diagram for push-pin connectors to ensure proper operation? Hopefully don"t have to buy new unit and can be repaired.Reply
InyoPools Product Specialist Matt S. Posted: 10/11/2021
The cord is not replaceable. A new cell would be necessary to get your salt chlorine generator running again.Reply
InyoPools Product Specialist Dennis R. Posted: 8/24/2015
john - Hayward does not sell direct to the customer. Give us a call at 877-372-6038. You should be able to get through to one of our service reps quickly.Reply
john Posted: 8/24/2015
I would like to order a self fan so that I can clean, generating chlorine filter. I tried all your numbers I have tried emails, without success all I would like to know is if I can purchase it from Hayward or do I have to go to a dealer.Reply
InyoPools Product Specialist Dennis R. Posted: 6/29/2015
Mike - Causes for little or no chlorine residual. The Hayward Aqua Rite switch is in the "Off" position. The Desired Output % adjustment setting is too low. The stabilizer (cyanuric acid) level is low. The filter pump time is too short (8 hours is average). The salt level is too high or too low (ideal 3200 ppm). The water temperature is warm and this causes a higher demand for chlorine. The water temperature is too low (below 50ºF) and this causes the Aqua Rite to stop generating. There is excessive scaling on the cell.Reply
Mike Posted: 6/28/2015
Replaced turbo cell with new one. Test strip shows plenty of salt. The cell is not producing enough chlorine even at 50% four hours a day. What's up? How can I fix it?Reply
InyoPools Product Specialist Dennis R. Posted: 5/30/2015
MIKE ODEN - You would have to replace the whole cell, if the outside cell casing cracked. I would check with Hayward /Goldline to see if they might replace it. Some of these cells have a 3 year warranty. Their number is 1-866-722-2100.Reply
MIKE ODEN Posted: 5/27/2015
MY CASING FOR MY TURBO CELL CRACKED WHEN PRESSURE WAS APPLIED.I JUST NEED THIS PART ONLY.GLX TURBO CELL 5.ONE YEAR OLD.BOUGHT JULY 2 2013Reply
InyoPools Product Specialist Dennis R. Posted: 7/11/2014
Chris - I haven't seen this problem before. I would suggest calling Hayward/Goldline at 866-772-2100. They should be able to resolve this issue for you.Reply
chris Posted: 7/9/2014
Help. We have an Aquarite and the power and generating lights comd on for abou 15 seconds and then go off. They will stay off about 15 seconds and then come back on. They just keep repeating this cycle. What could be wrong?Reply
InyoPools Product Specialist Dennis R. Posted: 5/25/2014
bob - I don't know the answer to your problem but here's a link to the AguaRite owner's manual. Trouble shooting starts on page 14. You may see other problem indicators in this list, or if not , contact Goldline tech support at the number provided at the start of the Troubleshooting section.Reply
bob Posted: 5/22/2014
My old salt water generator was 5 years old and was replaced I installed a new and it does not generate salt my indicator reads 4200 ppm and says salt too high it has turned green and test strip says no salt help!Reply
Bob Posted: 12/12/2013
Thanks that is exactly what it wasReply
InyoPools Product Specialist Dennis R. Posted: 12/6/2013
bob - According to the Hayward/Goldline rep, you may have inadvertently reset the cell size in your programming designation that you have a smaller cell than you actually have installed. Call Hayward/Goldline at 908 351-5400 X7961 for specific troubleshooting information.Reply
Bob Posted: 12/6/2013
My display reads Hi. The salt reading checked by my pool store is 2400. Do I need a new cell?Reply
InyoPools Product Specialist Dennis R. Posted: 6/26/2013
Bad Circuit Board - According to an authorized dealer for Hayward, if "no cell power" is displayed on your Aqua Rite panel or no LED lights are on, you generally need a new printed circuit board. But check your wiring first to make sure you have power to the unit.Reply
InyoPools Product Specialist Dennis R. Posted: 4/8/2013
Ralph - The cell can be positioned either way. In fact, the manufacturer recommends that you reverse the cell every time you clean it to extend the life of the cell.Reply
Ralph Posted: 4/7/2013
your picture shows the cord on the top when unscrewing and then on the bottom when reinstalling. Which is correct?Reply
InyoPools Product Specialist Dennis R. Posted: 10/12/2012
tonyptex - If you keep the water chemistry balanced, a cell will typically last 4-5 years. On the display panel, if your display shows "-Pcb-" and all red/yellow LEDs are illuminated, you may have a faulty printed circuit board. Call service.Reply
tonyptex Posted: 10/11/2012
Can anyone tell me what the average life of the cell is? How do I know if I need to change out the display panel as well?Reply
jersstuff Posted: 9/1/2012
Thank you for the information; reversing the cell each time I clean it, which will prolong the cell life.Reply
InyoPools Product Specialist Dennis R. Posted: 7/26/2012
Redman -I would call Hayward/Goldline on this one. Their number is 908-355-7995.Reply
Redman Posted: 7/25/2012
I have the exact same problem as "User: dead in the water" from November 2011 (see below). Was there a solution to this problem?Comment: i replaced it and salt reads 2000 still but High Salt light comes on. Instructions say reprogramming my be necessary, but following their instructions it does not give me the options it says it should
Reply
InyoPools Product Specialist Dennis R. Posted: 7/20/2012
HELPme - First check you connections to the cell then give Hayward/Goldline a call on this one. Their number is 908-355-7995.Reply
HELP me Posted: 7/18/2012
My aqualogic control keeps reading "No Cell Power" and system is not making any chlorine, pool is starting to get green. Can anyone help ? Do I have to replace the board ?Reply
deidra Posted: 6/29/2012
We replaced our salt cell with a t-cell 15. We have Hayward Swim Pure plus. The "Check salt" and "inspect cell" LEDs are on steady. Any suggestions?Reply
InyoPools Product Specialist Dennis R. Posted: 6/1/2012
ARMY - To get a copy of an AquaRite owner's manual: Go to the bottom of our website home page. Click Owner's Manuals - right hand corner. In Mfg list click Goldline Controls, then click AquaRite.Reply
InyoPools Product Specialist Dennis R. Posted: 5/31/2012
HELP - Please give Hayward a call on this one. They will be better able to troubleshoot your problem. Their number is 908-355-7995.Reply
ARMY Posted: 5/30/2012
CAN ANYOWNE HELP ME .I CANT FIND A MANUAL FOR THE AQUARITE CONTROL .
THE L.E.D. SCREEN SHOWS ALL KINDS OF NUMBERS , I WOULD LIKE TO UNDERSTAND WHAT THE LED SCREEN IS TELLING ME.
THANKS.
Reply
HELP Posted: 5/27/2012
i got Aquarite unit seen 2005 , i just got a new t-cell-15 put in ,the light for generate clorine not even on. and i try to put to auto and Super chlorinate try to change the t-cell, not things show up on the displayed about t-cell at allplease help TX
Reply
Russ Posted: 5/21/2012
If your salt level is reading high make sure your system is set to the correct cell size ie T9 vs T15 you can change the size setting by moving from auto to super chlorinate while the display is on the cell size reading. This can get reset very easily with power outages or like my kids who play with the pool settings?Reply
InyoPools Product Specialist Dennis R. Posted: 12/6/2011
Chuck - We recommend calling the manufacturer, Goldline Controls, on this issue. Their is 888 921-7665.Reply
Chuck Posted: 12/5/2011
I have a message on control panel "No cell power" Aqua logic unit. Where is the problem? Can you help?
Reply
InyoPools Product Specialist Dennis R. Posted: 11/17/2011
Jon, Thank you for your comment. You are correct and I have changed the guide to reflect your comment.Reply
Jon Posted: 11/15/2011
My goldline manual says water can flow in either direction through the cell. Every time I take it out to clean it, I reverse the direction.Reply
dead in the water Posted: 9/23/2011
i replaced it and salt reads 2000 still but High Salt light comes on. Instructions say reprogramming my be necessary, but following their instructions it does not give me the options it says it shouldReply
poolyboy Posted: 7/30/2011
That is crazy I did the same thing and looked at how the power cord was facing and it was backasswords.. And in that pic. the original was backasswords to. I bet thier was nuthen even wrong with the first one.Reply
InyoPools Product Specialist Dennis R. Posted: 5/29/2011
The .original cell was installed incorrectlyReply
Ben Posted: 5/26/2011
If the power cord should be closest to the pool, why is the original not positioned that way?Reply
bill wilson Posted: 3/31/2011
why wire to poolsideReply